AC Rezistan Chaj Bank
R103kw / 400V / 50Hz chaj bank se yon bank chaj rezistan devlope ak pwodwi pa konpayi nou an. Bank chaj la ka pote soti nan 25% tès dezekilib ak faktè pouvwa nan 1.0.
REZIME PWODWI
R103kw / 400V / 50Hz chaj bank se yon bank chaj rezistan devlope ak pwodwi pa konpayi nou an. Bank chaj la ka pote soti nan 25% tès dezekilib ak faktè pouvwa nan 1.0. Li adopte twa-faz kat sistèm fil epi yo ka pote soti nan tès chaj ekilibre pou mete dèlko, transfòmatè, ups ak lòt ekipman ekipman pou pouvwa.
FOTO PWODWI
SENARYO APLIKASYON
PARAMÈT PASYÈL
Remak: tout paramèt yo se pou referans sèlman epi yo ka Customized | |
Non pwodwi | bank chaj rezistif |
Espesifikasyon | R500kW / 400V / 690V / 50Hz |
Fòmasyon | Yon bank chaj (Ki gen ladan chaj rezistans sèk, eleman kontwòl elektrik, mezi ak sistèm kontwòl) |
chaj etap | Dapre bezwen kliyan |
Koneksyon chaj | ba kwiv |
Rezistans | Chak eleman rezistans: izolasyon impedance DC1000V/100MΩ pi wo a Reziste vòltaj ac 2000v pou 5min Rezistans erè nan chak tib rezistans: ±3% |
Chaj kontwòl | Kontwòl manyèl lokal, kontwòl otomatik lokal yo oswa kontwòl otomatik aleka ka chwazi |
chaje pwesizyon | Mwens pase oswa egal a 3% |
Twa faz ekilib | Degre degre inegal mwens pase oswa egal a 3% |
etap minimòm | 1kW |
Mòd k ap travay | Travay kontinyèl |
Chaj pwoteksyon | Kout sikwi, tanperati ki wo, pwoteksyon fayit |
Pouvwa ekstèn | TN-C,380V / 50Hz |
Refwadisman mòd | Fòse lè refwadisman, bò kote lè a oswa tèt lè a |
Izolasyon klas | F |
Presizyon mezi | Presizyon nan ekspozisyon se 0.5, presizyon nan echantiyon an se 0.2 |
Ekspozisyon paramèt elektrik | Twa faz vòltaj, twa-faz aktyèl, frekans, pouvwa, elatriye |
Chaj ekspansyon | Ekspansyon paralèl nan plizyè resipyan chaj |
Standard | Rankontre estanda entènasyonal, estanda bato, estanda militè ak estanda telekominikasyon |
Koulè | Customized |
tanperati anbisye | -20 ° C a 50 ° C |
Imidite | Jiska 100% |
Altitid | Jiska 2500m |
Pwesyon atmosferik | 86 a 106kPa |
PLIS ESPESIFIKASYON
Remak: tout paramèt yo se pou referans sèlman epi yo ka Customized | ||||
Pouvwa(kW) | Vòltaj (kV) | Frekans(Hz) | Gwosè(mm, L*W*H) | Pwa (Kg) |
Ba vòltaj | ||||
100 | 0.4 | 50 | 1100*900*1000 | 320 |
200 | 0.4 | 50 | 1350*1100*1100 | 450 |
300 | 0.4 | 50 | 1500*1200*1200 | 650 |
400 | 0.4 | 50 | 1700*1500*1500 | 830 |
500 | 0.4 | 50 | 1700*1600*1600 | 950 |
600 | 0.4 | 50 | 1800*1600*1600 | 1150 |
800 | 0.4 | 50 | 1900*1800*1700 | 1900 |
1000 | 0.4 | 50 | 2300*1700*2100 | 2100 |
1200 | 0.4 | 50 | 2500*1800*2200 | 2300 |
1500 | 0.4 | 50 | 2500*1860*2300 | 2600 |
1800 | 0.4 | 50 | 3000*2000*2300 | 4000 |
2000 | 0.4 | 50 | 3000*2000*2300 | 5000 |
2500 | 0.4 | 50 | 4000*2438*2500 | 6000 |
3000 | 0.4 | 50 | 6000*2438*2500 | 7000 |
Mwayen vòltaj | ||||
1000 | 6/10.5 | 50/60 | 3000*2438*2500 | 3500 |
1200 | 6/10.5 | 50/60 | 4000*2438*2500 | 3900 |
1500 | 6/10.5 | 50/60 | 4000*2438*2500 | 4500 |
1600 | 6/10.5 | 50/60 | 5000*2438*2500 | 5000 |
1800 | 6/10.5 | 50/60 | 5000*2438*2500 | 6500 |
2000 | 6/10.5 | 50/60 | 6000*2438*2500 | 7500 |
2200 | 6/10.5 | 50/60 | 6000*2438*2500 | 8000 |
2500 | 6/10.5 | 50/60 | 6000*2438*2500 | 10000 |
3000 | 6/10.5 | 50/60 | 7000*2438*2500 | 12000 |
4000 | 6/10.5 | 50/60 | 8000*2438*2500 | 14000 |
5000 | 6/10.5 | 50/60 | 9000*2438*2500 | 15000 |
6000 | 6/10.5 | 50/60 | 12000*2438*2500 | 16000 |
7000 | 6/10.5 | 50/60 | 12000*2438*2500 | 17000 |
8000 | 6/10.5 | 50/60 | 12000*2438*2500 | 18000 |
TRANSPÒ AK ENSTALE
Kat kwen tèt yo nan bank chaj la yo bay ak twou leve ak kat kwen anba yo bay ak roulo fasilite chaje, transpò ak enstalasyon mobil.
ELEVANT STANDARDS
Konsepsyon, pwodiksyon ak sèvis nan sistèm lan dwe nan akò strik ak kondisyon ki nan sistèm jesyon bon jan kalite (GB / T19001-2008) ak refere a estanda sa yo (kèk nan yo ki ka pa apwopriye pou aplikasyon pratik, ak konplo a pwodiksyon final nan sistèm lan dwe sijè a akò teknik la teknik dakò pa tou de pati yo):
estanda nasyonal
GB / T 2820.5-2009 Resipwofòte motè konbisyon entèn kondwi AC dèlko AC etabli Pati 5: dèlko kouche
GB / T 13032-2010 Marin dyezèl mete
GB / T 1029-2005 metòd tès pou twa motè senkronik
GB 14711-2006 Sekirite pou machin ti ak mwayen Wotasyon machin elektrik
estanda militè
GJB 5785-2006 espesifikasyon jeneral pou militè dèlko konbisyon entèn
GJB 235-1997 espesifikasyon jeneral pou estasyon pouvwa militè AC mobil
GJB 1488-92 metòd tès jeneral pou ekipman pou pouvwa nan motè konbisyon entèn militè
KALIFIKASYON ONORÈ
Depi kreyasyon li yo, Rata te jwenn 16 sètifika sèvis piblik patant ak 8 sètifika lojisyèl copyright copyright, e li te rekonèt kòm yon antrepriz nasyonal gwo teknoloji.
Baj popilè: akonpaye bank chaj rezistif, Lachin, Swèd, manifaktirè, faktori, Customized, pri, sitasyon pi ba